Por favor, use este identificador para citar o enlazar este ítem: http://cibnor.repositorioinstitucional.mx/jspui/handle/1001/1007
Evaluation of biopsy systems for sampling white shark Carcharodon carcharias (Lamniformes: Lamnidae) muscle for stable isotope analysis
Evaluación de métodos de colecta de músculo de tiburón blanco Carcharodon carcharias (Lamniformes: Lamnidae) para análisis de isótopos estables
MARIO JAIME RIVERA
Javier Caraveo Patiño
Edgar Mauricio Hoyos Padilla
Felipe Galván Magaña
Acceso Abierto
Atribución-NoComercial-SinDerivadas
http://www.revbiolmar.cl/index.php?option=com_content&view=article&id=1134&Itemid=62&lang=es
Tiburón blanco, métodos para obtención de biopsias, señales isotópicas de carbono y nitrógeno, músculo
White shark, biopsy methods, isotopic signatures of carbon and nitrogen, muscle
"Los métodos manuales para la obtención de biopsias de tiburones que nadan libremente han tenido tasas de éxito limitadas para diferentes tipos de tejidos. El músculo es un tejido importante, sin embargo muchos métodos fallan en recolectarlo y sólo obtienen dermis. Se describe el uso de 3 diferentes sistemas de dardos para la obtención de biopsias y se evaluó la tasa de éxito en la recolecta de músculo de tiburón blanco en Isla Guadalupe, México. Los resultados sugieren que el sistema de Reeb & Best (dardo RB) fue el mejor para obtener tejido muscular debido a que el grosor de la dermis del tiburón blanco es ~1,0 cm. El análisis de isótopos estables entre los diferentes tejidos (dermis y músculo) sugiere una diferente tasa de recambio. No hubo diferencia significativa entre los valores isotópicos de las regiones profunda y superficial del músculo. Una biopsia de 5,0 cm de longitud podría ser suficiente para obtener músculo para realizar análisis de isótopos estables u otros."
"Manual biopsy methods are typically used to obtain samples from free-swimming sharks but have had limited or varied success rates for different types of tissues. Muscle is the tissue desired when biopsies are used, however many methods fail to collect muscle and only collect dermis. The use of 3 different dart systems was described for manual biopsies and the success rate and tissue yield from white sharks at Isla Guadalupe, México was evaluated. Results suggest that the Reeb & Best biopsy system (RB dart) was best to biopsy muscle tissue because this dart was able to penetrate the dermal layer of white sharks is ~1.0 cm. Stable isotope analysis revealed no significant difference between outer and deeper muscle regions. A biopsy of 5.0 cm or less would be sufficient to obtain enough muscle for stable isotope and other kinds of analysis."
Facultad de Ciencias del Mar y de Recursos Naturales Universidad de Valparaíso
2013
Artículo
Revista de Biología Marina y Oceanografía
Español
HISTOLOGÍA ANIMAL
Versión publicada
publishedVersion - Versión publicada
Aparece en las colecciones: Artículos

Cargar archivos:


Fichero Tamaño Formato  
jaime_m 2013 v48n2pp345-351.pdf179.7 kBAdobe PDFVisualizar/Abrir